Progress Update: Humidification System Design

The Requirements Analysis and Design Document has been completed! From this the final designs and schematics of the various subsystems have been completed. In this post we look at some of the details of the Humidification System.

Humidification System: 

The following block diagram gives an overview of the system and it’s various components.

Block Diagram Summary of Humidification System
Block Diagram Summary of Humidification System

In reality, however, there will be two test chambers connected to other system elements, all controlled through the MCU and the valving.

Humidity Generator: 

Several different humidity generation schemes were considered, but the final design was chosen based on Reliability, Cost, Portability and Safety considerations.

The final design is an active bubble humidifier, which humidifies air by bubbling it through a warm water bath. This design is highly reliable and safe. It can be operated completely on DC voltages and components are easily sourced and cheaply available.

The final design for the Humidity Generator. Air is bubbled through warm/hot water and is pumped into the test chambers. The entire air path is closed, allowing humidity to build upon itself (increasing efficiency), retain test chamber heat, and reduce potential for harmful fumes escaping the test chamber.
The final design for the Humidity Generator. Air is bubbled through warm/hot water and is pumped into the test chambers. The entire air path is closed, allowing humidity to build upon itself (increasing efficiency), retain test chamber heat, and reduce potential for harmful fumes escaping the test chamber.

Dehumidification: 

In order to conduct tests below ambient humidity a dehumidification system is required. After considering multiple dehumidification options a replaceable and recyclable chemical desiccant was chosen.

A chemical desiccant 'snake' is used for dehumidification.
A chemical desiccant ‘snake’ is used for dehumidification.

A silica gel desiccant was chosen due to its easy and cheap availability, excellent absorption characteristics and high temperature operation.

Humidity Valving: 

A single Humidity Generator and Dehumidifier needs to be able to service both test chambers. In order to achieve this a valving system is required to switch airflow as required. High temperature valves are required due to oven operating temperature. The system is also low pressure, requiring direct acting valves. Single way valves were chosen for cost, simplicity and sourcing reasons.

The valving and tubing for the humidification system is summarised in the above pneumatic schematic.
The valving and tubing for the humidification system is summarised in the above pneumatic schematic. “Diode Symbols” represent one-way check valves, “switch symbols” represent direct acting, one-way solenoid valves. Y-connectors are used to join 3 tubes together.

Humidification Valve Driver: 

In order to control all these valves, an amplification circuit is required to convert the MCU signal into power for the solenoids. Additionally, in order to minimise the number of MCU pins required a High Power Shift Register and Relays are used to convert a serial 5V signal from the MCU to a parrallel 12V signal to drive the solenoids. This electrical schematic is shown below.

Electrical Schematic of the circuit required to amplify and interpret the MCU signal into a power signal to drive the Solenoid Valves. The circuit also contains elements to amplify and drive the DC Air Pump as well as the Heaters for the Humidifier.
Electrical Schematic of the circuit required to amplify and interpret the MCU signal into a power signal to drive the Solenoid Valves. The circuit also contains elements to amplify and drive the DC Air Pump as well as the Heaters for the Humidifier.

Construction: 

Most of the components for the humidification system have arrived and construction is well under way.

Until next time!
-Rohan